TLD Triple Loop-Powered Display Digital Panel Meter

ATTENTION: THIS ITEM TO BE DISCONTINUED

PLEASE NOTE THAT NO NEW ORDERS WILL BE TAKEN FOR THIS MODEL AFTER 12/2016.  CLICK HERE FOR DETAILS OR SEE THE DESCRIPTION BELOW FOR REPLACEMENT INFORMATION.

Product Description:

PLEASE NOTE THAT NO NEW ORDERS WILL BE TAKEN FOR THIS MODEL AFTER 12/2016.  CLICK HERE FOR DETAILS OR SEE MODEL NTM-A AS A REPLACEMENT.

OTEK’s TLD (3.78"W x 3.78"H x 3"D) has 3 independent and isolated displays, driven from their own current loop (or external power) to concurrently display any 3 parameters which are all fit into a 1/4 DIN housing.

You talk, OTEK listens! We were requested to put 3 LPE's in one compact surface mount package with larger digits, like our HI-Q126, so we did it! Now you can have 3 independent and isolated displays, driven from their own current loop (or external power) to concurrently display any 3 parameters.  
 
Several options are available on the TLD: (See Ordering Information). You can have it as a:
1. 4-20mA input loop powered. (Powerless™)
2. V/mADC Signal powered. (Powerless™)
3. Externally powered for V, mA DC & True RMS, TC, RTD, S-G, %RH, pH ORP, Hz, etc.
 
The Grades Are: Nuclear (10CFR50B), Mil-Spec (to your MilStd.) or Industrial (to published specs.). The Power Inputs Are: Loop Powered, 5-48VDC or 90-265VAC.You can even power your 4-20mA transmitters with the optional 28VDC compliance. The TLD is available in plastic or metal case (for Mil & Nuclear) conforming 1/4 DIN (92 x 92mm) panel cutout, only 3" Deep. Intrinsically Safe (I.S.) versions on request. See Foot Note under Ordering Information.
 
FAQ:
1. Can I change the scale in the ? eld? Yes. Span &   Zero are located on the front for each channel.
2. Can I change the display color sequence? Yes. Use #9 and specify when ordering.
3. Can I change the display designation? Yes. Use #9 and specify.
4. Can I change the input signal type in the ? eld? No.
5. Do you have Peak & Hold? Yes. It is standard.
6. More Questions? Call OTEK at 520-748-7900

 

Replacement Units:

Replace three old analog style meters in one compact case!

Features:

  • 0.6" 3 1/2 & 4 1/2 Digits
  • Colors: Blue (Top), Red (Middle), Amber (Bottom)
  • 1/4 DIN Housing
  • Signal or Loop Powered
  • 3 Isolated Channels (>500VRMS)
  • 3 Independent A/D
  • HiSpeed Peak/Hold
  • Low Burden
  • NEMA 4X, EMI/RFI
  • Loop or VDC Signal Powered or 5-48VDC/100-240VAC Power
  • 28-VDC Power for Transmitter
  • Nuclear, Mil-Spec, I.S. & Industrial
  • Lifetime Warranted

Suggested Uses:

  • 3 in 1 panel meter
  • Triple isolation for safety
  • Parasitic
  • Compact 1/4 DIN case
  • Replace three analog meters in one case

Additional Information:

Term Reference: 

OTEK's 1PM is our smallest LED Digital Panel Meter (and Loop Powered). The unit is only 1" x 1.3", with 0.33" LEDs.

OTEK brings you the World's smallest LED Digital Panel Meter (and Loop Powered). That is why we call it the 1PM!  The size does not affect its reliability, performance and accuracy and we even managed to add the over-range indicator above the MSD so you know you have exceeded the full scale range. We added the negative sign indicator ("-") below the MSD so you know your signal is negative. You can adjust the Zero & span (+30% range) via 12 turn potentiometers on the rear and connections are made via standard 0.1" center headers for P.C.B. or panel mount. For panel mount, a polarized ? lter is available on request. The 1PM is a typical example of OTEK's Custom and Semi-Custom capabilities. If it can be done, we can do it!

PLEASE NOTE THAT NO NEW ORDERS WILL BE TAKEN FOR THIS MODEL AFTER 12/2016.  CLICK HERE FOR DETAILS OR SEE MODEL NTM-D AS A REPLACEMENT

OTEK's DCS (3.26"W x 3.26"H x 1.69"D) is designed to replace our old 590 series meter as well the popular 3.5 barrel analog meters.

By popular demand we bring back the old "590" but with New Patented Technology so you can replace the old needle, fragile and inaccurate 19th Century Technology analog meters without changing your panel or wiring. Signal Powered: 4-20mA current loop and 4-30VDC, VAC, AAC, WAC & Hz-ideal for power line monitoring. Externally Powered: V & mADC, V & mA RMS, TC, RTD, Frequency (40-20KHz), pH (0-14), %RH, and customs. The external power options cover the entire industrial range of 5-32 VDC and 90-265VAC. Zero and Span adjustments (12 Turn Pots) are conveniently located on the front. Signal Conditioners:  20+ signal conditioners are available (see description) for Powerless™(Signal Powered) or externally powered applications.The DCS performs a self-test (C.O.P.) on power up for approximately 2 seconds.

PLEASE NOTE THAT NO NEW ORDERS WILL BE TAKEN FOR THIS MODEL AFTER 12/2016. CLICK HERE FOR DETAILS OR SEE MODEL NTM-0 (horizontal 1/8 DIN) or NTM-B (vertical 1/8 DIN) AS REPLACEMENTS.

OTEK's SPM (3.78"W x 1.90"H x 2.70"D) is a signal or externally powered meter with an LED display.
 
With over 30 years in the Digital Panel Meter field, we had to bring you the best that technology would allow. The SPM is a combination of that expertise and newest technology in an industry's standard 1/8 DIN package. We started with a universal display (4 1/2 digit LED display) and embedded Sigma-Delta A/D. We added (Option 2) 3 1/2 LED .8" IF YOU DON’TSEE IT,ASK FOR IT!(Option 4) 4 LED .8" a "Bussed" mother board that we can add any of hundreds of designs from our 30+ years library to deliver the industry's only "Lifetime Warranted" Digital Panel Meter. Whether for Systems or just to monitor, control and/or communicate via Serial I/O. The modular construction of the SPM allows OTEK to customize to your needs without expensive N.R.E., set-ups or minimum orders.
 
Controller: When you order Serial I/O. (Digit 4 Options 1-3), you can order analog out (Digit 6) and/or relays (Digit 7) and we include math functions, X-Y tables & polynomials with it!
 
Displays: You can order the large 0.8" 3 1/2 or 4 digit LED or the 0.6" 4 1/2 LED. NEW white LED displays are now available!  Standard filter is red. For other colors use Option 9 on 8th digit and specify color (depending on availability).

The SRD (Serial Remote Display) brings information from a central computer network or SCADA system to a remote location with easy-to-read LCD or LED digits. In addition to being a remote digital indicator or slave display, the SRD can function as a programmable process controller, with both manual and reading-based operation. It is designed to work with any RS-232, RS-485, or USB network through an intuitive command set to display a message and control its relay and DAC outputs accordingly. In 1/8 DIN packaging, the SRD is easy to install and provides a simple solution to your industrial remote networking needs.

PLEASE NOTE THAT NO NEW ORDERS WILL BE TAKEN FOR THIS MODEL AFTER 12/2016.  CLICK HERE FOR DETAILS OR SEE MODEL NTM-3 AS A REPLACEMENT.

OTEK's TAC (4.35"W x 4.35"H) is a triple A.C. signal powered panel meter for AC volts, amps, watts and Hz.

OTEK has taken its ACS Series and by popular demand combined 3 out of 4 A.C. variables in one  case. The TAC (Triple A.C. Signal Powered) Series is available in either plastic or metal ANSI 4" (Switchboard). The TAC has no depth behind the panel ( only 1 1/2" on the front). The TAC displays any 3 AC Variables such as V, A&W, or V, A & Hz single phase or V/A/W 3 phase delta or WY on its large 3 1/2 digit display behind the NEMA 4X ? lter. The Patented (#4,908,569) and Patent Pending Technology allows the TAC to power itself directly from the signal it measures either directly or through a P.T. & C.T. without affecting their integrity. Single Phase: Monitor with one small instrument any 3 out of 4 variables (See Ordering Information).Three (3) Phase: You have a choice of 3 each single phase "TACs" (one for each phase) or one "TAC" for VOLTS (Phases A, B & C) one for AMPS, one for WATTS and one for HERTZ. Contact OTEK for your custom con? guration.
 
IMPORTANT NOTES: Just like analog meters, if the signal is too small, the TAC will not function but it does not mean there is no power. Always use CAUTION when connecting/disconnecting the TAC from the mains or PT/CT. There is NO internal isolation from V & A when using Watts function. Always use a C.T. and P.T.

 

PLEASE NOTE THAT NO NEW ORDERS WILL BE TAKEN FOR THIS MODEL AFTER 12/2016.  CLICK HERE FOR DETAILS OR SEE MODEL NTM-A AS A REPLACEMENT.

The TAD (3.78"W x 3.78"H x 3"D) is a triple A.C. signal powered display available in either plastic or metal 1/4 DIN cases.

OTEK has taken its ACS Series and by popular demand combined 3 out of 4 A.C. variables in one  case. The TAD (Triple A.C. Signal Powered Display) Series is available in either plastic or metal 1/4 DIN cases. The TAD displays any 3 AC Variables such as V, A&W, or V, A & Hz single phase or V/A/W 3 phase delta or WY on its large display behind the NEMA 4X ? lter. The Patented (#4,908,569) and Patent Pending Technology allows the TAD to power itself directly from the signal it measures either directly or through a P.T. & C.T. without affecting their integrity. 
 
IMPORTANT NOTES: Single Phase: Monitor with one small instrument any 3 out of 4 variables (See Ordering Information). Three (3) Phase: You have a choice of 3 each single phase "TADs" (one for each phase) or one "TAD" for VOLTS (Phases A, B & C) one for AMPS, one for WATTS and one for HERTZ. Contact OTEK for your custom con?guration.Just like analog meters, if the signal is too small, the TAD will not function but it does not mean there is no power. Always use CAUTION when connecting/disconnecting the TAD from the mains or PT/CT. There is NO internal isolation from V & A when using Watts function. Always use a C.T. and P.T.
 

Pages